管涵管道安裝技術交底.doc
進入下載頁
交底內容:
本工程管涵位于K0+288里程處,為鋼筋混凝土管。
一、管材:
1. 本工程采用的鋼筋混凝土管必須保證可以承受6.0m覆土壓力,為平口管。
2. 鋼筋混凝土管必須在內部熱涂瀝青一道后再安裝連接。
二、管涵基礎:
1. 本工程管涵基礎采用鋼筋混凝土管1800混凝土基礎,具體圖紙見國家建筑標準設計給水排水標準圖集(95S516,第6頁)。
2. 開挖的溝槽人工整平后,標高復測無誤即鋪設砂碎石墊層,整平夯實后再次復測標高,無誤再支模澆注管涵基礎。
混凝土強度等級為≥C10,第一次澆注(管座平基)的高度為300mm,應振搗密
Cards on the table contents:
The project culvert at K0 +288 Mileage for reinforced concrete pipe.
1, pipe:
1. This project used in reinforced concrete pipe must be guaranteed to withstand 6.0m overburden pressure, as the flat mouth tube.
2. Reinforced concrete pipe must be an internal thermal coating asphalt and then install the connection.
Second, culvert foundation:
1. This project based on reinforced concrete culvert pipe 1800 concrete foundation, concrete, see the National Building Standard Design Drawings Water Standard Atlas (95S516, p. 6).
2. Excavation trench were neat square, the level retest is correct that the laying sand gravel pads, leveling retest again after compaction level, and correct re-cast culvert foundation formwork.
Concrete strength grade ≥ C10, the first casting (pipe seat leveling) the height of 300mm, should be vibrated close