粘貼擠塑泡沫板、鍍鋅鋼絲網(wǎng)、聚合物砂漿抹面外墻外保溫施工工藝.doc
進入下載頁
一、編制依據(jù)
1、88J2-4墻身——外墻保溫。
2、FEWEISTM外墻外保溫系統(tǒng)
3、外墻外保溫建筑構造圖集99ZJ105(一)
4、88J2—9墻身——外墻保溫(節(jié)能65%)
二、施工條件
(1)基層墻體經(jīng)過工程驗收達到質量標準,方可進行外墻外保溫施工。
(2)基體墻體上的脫模劑、混凝土殘渣、灰土等雜物必須清理干凈,墻面平整超差部分應剔鑿或修補。
(3)伸出墻面的(設備、管道)連接件已安裝完畢,并留出外保溫施工的余地。
(4)門窗洞口經(jīng)過驗收,洞口尺寸、位置達到設計和質量要求,門窗框或輔框應已立完。
(5)建筑物基層在正負風壓作用下其層間位移小于1/360。
(6)外墻外保溫施工的墻體基面的尺寸允許偏差:
1, prepared on the basis
1,88 J2-4 wall - external wall insulation.
2, FEWEISTM exterior insulation system
3, exterior insulation building construction Atlas 99ZJ105 (1)
4,88 J2-9 wall - external wall insulation (saving 65%)
Second, construction conditions
(1) The primary wall after project is completed to meet quality standards before construction for exterior insulation.
(2) release agent on the substrate walls, concrete debris, dust and other debris must be clean, smooth wall section should tick the chisel-tolerance or repair.
(3) out of the wall (equipment, piping) connectors have been installed, and left the room to go out insulation construction.
(4) window and door openings through inspection, the hole size and location to meet the design and quality requirements, the door window frame should have been established or completed secondary box.
(5) building the grassroots in the positive and negative air pressure under the layer displacement is less than 1 / 360.
(6) Construction of the wall external thermal insulation the size of base surface tolerance: